Row Denco

Row-DENCO

INTRODUCTION
FAST FACTS

Row-DENCO brings a new direction to your datacentre.

  • Horizontal airflow – ideal for rooms with low height
  • Consistent design for refrigerant and chilled water
  • Scalable – can be installed as your room is populated
  • Positioned next to server for good heat extraction
  • Available from 10 kW to 30 kW
  • Available as Direct Expansion (DX) or Chilled Water (CW)
  • 3 capacity sizes for DX, 4 capacity sizes for CW
  • Unit footprint either 300 x 1000 mm or 300 x 1200 mm
  • Multiple airflow directions available
  • Integrated unit wheels for unit positioning
  • Unit connections both top and bottom
  • Networking between units available
  • Building Management System (BMS) interfaces available
  • Humidity options available

PRODUCT DETAILS

The data center industry is no longer static; designers and managers must consider both the existing requirements for performance and output and they must predict the future for their data center.  They need a product with scalability, adaptability, dependability, consistency and simplicity.  They need these to allow for their data center to grow and evolve efficiently.  Row-DENCO can provide all these features, and more, to give the efficient operations you require.

With a width of 300mm and a rear to front airflow, Row-DENCO units can be associated with particular servers, rather than with a room. This enables a direct relationship between the server and its source of cool air, reducing or eliminating the need to create excess or future capacity.

A highly adaptable method for expansion of an existing data center. The design requires no floor or ceiling void and has a small footprint (between 0.30 and 0.36 m²). It includes easy and simple connection points that allow for fast installation from either above or below.

Designed for easy for N+1 configuration. The units can be networked together, allowing for a duty-standby configuration setup. The fans, as standard, operate ‘running redundancy’ within each unit; therefore if a fan needs replacing, the others can increase their speed to cover the airflow requirements whilst you can perform a hot swap.

Available as both direct expansion and chilled water units, but shares the same design principles and features: mechanical connections available at the top and bottom, humidifier available for both, casing sizes and airflow configurations are the same for both types.

Row-DENCO units make the delivery, installation, commissioning and maintenance as straight-forward as possible. By using integrated wheels to give easy positioning on your site or good accessibility to all internal components for maintenance. The design helps lower risks to performance with each airflow localized to particular servers.

PRODUCT FEATURES

The supply air can be directed in 3 individual directions or as both left and right.

Available as both direct expansion and chilled water units, but shares the same design principles and features: mechanical connections available at the top and bottom, humidifier available for both, casing and airflow options are the same for both types.

Designed for easy for N+1 configuration, they units can be networked together, allowing for a duty-standby configuration setup.

With a width of 300mm and a rear to front airflow, Row-DENCO units can be positioned with particular servers, rather than with a room.